When the No. 2 heater control sub-assembly is operated, the heater relay will turn on to allow current to flow to the blower motor and then the motor will start rotating. Operating the No. 2 heater control sub-assembly switches the current flow between the blower resistor and body ground, thus, shifting the rotation speed of the blower motor with fan sub-assembly.
Inspect the fuses for circuits related to this system before performing the following procedure.
Remove the HTR relay from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage is applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 4 | Battery voltage is not applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G55 blower motor with fan sub-assembly connector.
| *A | for LHD |
| *B | for RHD |
Connect a positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 1, and check that the motor operates.
The blower motor with fan sub-assembly operates smoothly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *A | for LHD |
| *B | for RHD |
Remove the blower resistor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (E) - 1 (HI) | Always | 3.12 to 3.60 Ω |
| 2 (M1) - 1 (HI) | Always | 1.45 to 1.67 Ω |
| 3 (M2) - 1 (HI) | Always | 0.52 to 0.60 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (E) - 4 (HI) | Always | 3.12 to 3.60 Ω |
| 3 (M1) - 4 (HI) | Always | 1.45 to 1.67 Ω |
| 2 (M2) - 4 (HI) | Always | 0.52 to 0.60 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *A | Model code except: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV |
| *B | Model code: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV |
| *1 | Blower Switch OFF Position |
| *2 | Blower Switch LO Position |
| *3 | Blower Switch M1 Position |
| *4 | Blower Switch M2 Position |
| *5 | Blower Switch HI Position |
Remove the No. 2 heater control sub-assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (LO), 6 (HI), 8 (M1), 10 (M2) - 5 (E) | Blower switch off | 10 kΩ or higher |
| 1 (LO) - 5 (E) | Blower switch LO | Below 1 Ω |
| 1 (LO), 8 (M1) - 5 (E) | Blower switch LO to M1 | Below 1 Ω |
| 1 (LO), 8 (M1) - 5 (E) | Blower switch M1 | Below 1 Ω |
| 1 (LO), 8 (M1), 10 (M2) - 5 (E) | Blower switch M1 to M2 | Below 1 Ω |
| 1 (LO), 10 (M2) - 5 (E) | Blower switch M2 | Below 1 Ω |
| 1 (LO), 10 (M2), 6 (HI) - 5 (E) | Blower switch M2 to HI | Below 1 Ω |
| 1 (LO), 6 (HI) - 5 (E) | Blower switch HI | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 4 (LO), 6 (HI), 9 (M1), 10 (M2) - 5 (E) | Blower switch off | 10 kΩ or higher |
| 4 (LO) - 5 (E) | Blower switch LO | Below 1 Ω |
| 4 (LO), 9 (M1) - 5 (E) | Blower switch LO to M1 | Below 1 Ω |
| 4 (LO), 9 (M1) - 5 (E) | Blower switch M1 | Below 1 Ω |
| 4 (LO), 9 (M1), 10 (M2) - 5 (E) | Blower switch M1 to M2 | Below 1 Ω |
| 4 (LO), 10 (M2) - 5 (E) | Blower switch M2 | Below 1 Ω |
| 4 (LO), 10 (M2), 6 (HI) - 5 (E) | Blower switch M2 to HI | Below 1 Ω |
| 4 (LO), 6 (HI) - 5 (E) | Blower switch HI | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | HTR relay |
Remove the HTR relay from the No. 2 engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| HTR relay terminal 1 - Body ground | Ignition switch ON | 11 to 14 V |
| HTR relay terminal 5 - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| HTR relay terminal 4 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the HTR relay from the No. 2 engine room relay block.
Disconnect the G80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| HTR relay terminal 2 - G80-14 (HR) | Always | Below 1 Ω |
| HTR relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G80 air conditioning amplifier assembly connector.
Disconnect the G21 No. 2 heater control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G80-17 (SBLW) - G21-1 (LO) | Always | Below 1 Ω |
| G80-17 (SBLW) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G80-17 (SBLW) - G21-4 (LO) | Always | Below 1 Ω |
| G80-17 (SBLW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G56 blower resistor connector.
Disconnect the G21 No. 2 heater control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*1: Model code except: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV *2: Model code: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV |
||
| G56-1 (HI) - G21-6 (HI) | Always | Below 1 Ω |
| G56-3 (M2) - G21-10 (M2) | Always | Below 1 Ω |
| G56-2 (M1) - G21-8 (M1)*1
G56-2 (M1) - G21-9 (M1)*2 |
Always | Below 1 Ω |
| G56-4 (E) - Body ground | Always | Below 1 Ω |
| G21-5 (E) - Body ground | Always | Below 1 Ω |
| G56-1 (HI) - Body ground | Always | 10 kΩ or higher |
| G56-3 (M2) - Body ground | Always | 10 kΩ or higher |
| G56-2 (M1) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*1: Model code except: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV *2: Model code: ASA44R-ANTXKQ, ASA44R-ANFXKQ, ZSA42R-ANXXKQ, ZSA42R-ANFXKQ, ASA44L-ANTXKV, ASA44L-ANFXKV, ASA42L-ANTXKV, ASA42L-ANFXKV |
||
| G56-4 (HI) - G21-6 (HI) | Always | Below 1 Ω |
| G56-2 (M2) - G21-10 (M2) | Always | Below 1 Ω |
| G56-3 (M1) - G21-8 (M1)*1
G56-3 (M1) - G21-9 (M1)*2 |
Always | Below 1 Ω |
| G56-1 (E) - Body ground | Always | Below 1 Ω |
| G21-5 (E) - Body ground | Always | Below 1 Ω |
| G56-4 (HI) - Body ground | Always | 10 kΩ or higher |
| G56-2 (M2) - Body ground | Always | 10 kΩ or higher |
| G56-3 (M1) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G55 blower motor with fan sub-assembly connector.
Disconnect the G21 No. 2 heater control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G55-1 - G21-6 (HI) | Always | Below 1 Ω |
| G55-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the HTR relay connector.
Disconnect the G55 blower motor with fan sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| HTR relay terminal 3 - G55-2 | Always | Below 1 Ω |
| HTR relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG